MD14DD-P6B1– Snaige Medical Max Plus (bluetooth) – Medicinkylskåp med solid dörr, 130 liter

Medical Max Plus (bluetooth) – Medicinkylskåp med solid dörr, 130 liter

Artikelnr: SN-MD14DD-P6B1 Kategori:

Frågor om MD14DD-P6B1– Snaige Medical Max Plus (bluetooth) – Medicinkylskåp med solid dörr, 130 liter?

Ring 042-300 91 30 eller maila info@labteamet.com

Beskrivning

MD14DD-P6B1– Snaige Medical Max Plus (bluetooth) – Medicinkylskåp med solid dörr, 130 liter

Comply with DIN 13277
MAX PLUS line refrigerators have all the essential features and performance functions required to meet the performance criteria of the DIN 13277 standard. This standard provides the requirements and test specifications for medical and laboratory refrigerators and freezers.
Test method EN 60068-3
SNAIGĖ medical refrigerators are tested according to EN 60068-3 in order to ensure the stability and constancy of the internal temperature. The test method involves measuring the temperature at 15 different points inside the refrigerator.
Test method EN 60068-3
SNAIGĖ medical refrigerators are tested according to EN 60068-3 in order to ensure the stability and constancy of the internal temperature. The test method involves measuring the temperature at 15 different points inside the refrigerator.
Ecological and environmentally friendly
MAX PLUS line refrigerators are manufactured using only non-harmful, nonozone-depleting and non-greenhouse-effect refrigerating and insulating materials. Natural resource-saving materials and electricity from renewable energy sources are used in the refrigerator manufacturing process.
KEY FEATURES
Contactless control and register of temperature data and warnings
The CONTROLLA app makes it possible to connect to the refrigerator controller via a contactless network using. This app also enables control over the refrigerator, while the user can download temperature reports and view alert history. The temperature in the refrigerator controller is recorded every 20 minutes.
Temperature stability
The refrigerator is designed to maintain maximum stable temperature and minimal fluctuations. The maximum possible temperature change within the entire internal space of the refrigerator is only ± 1.8 °C. Thus, the internal microclimate is maintained, creating suitable conditions for the storage of medications and medicines.
Cooling system with circulating air
The SNAIGĖ smart fan for medical refrigerators operates very efficiently. It turns off as soon as the refrigerator door is opened, so the air circulation in the refrigerator stops. Once the door is closed, the fan starts again and the air circulation is resumed. This fan operation prevents rapid temperature changes and helps to maintain a stable temperature inside the refrigerator, contributing to the preservation of medicines and medications.
Protection against contact with cold surfaces
The evaporator of the refrigerator has a special cover so that medications and medicines do not have direct contact with the evaporator and do not get cold. In addition, this protection against contact with cold surfaces increases the temperature stability.
Integrated data logger
The memory of the SNAIGĖ pharmaceutical refrigerator electronic controller stores the last five alarm records (with alarm date and duration) and a 6-month temperature measurement summary (with measurement date and time) are stored in the memory of the MD40DDP301BEQ electronic controller. These data stored in the controller’s memory can be downloaded to the e-mail box via the CONTROLLA app. In addition, the app can be used to select the required period of temperature measurement summary: from one day to half a year.
Warning of electricity supply failure
In the event of the electricity supply failing, the battery of the MD40DD-P301BEQ provides sufficient energy for the registration of temperature readings and the operation of the warning signal (audio and visual) for the next 24 hours.
Warning temperature alarm
In order to ensure the maximum safety of stored medicines and medications, the integrated warning temperature alarm sends a warning signal with sound and image when a certain temperature value exceeds or falls below the set limit.
Warning register
Warning signals must be monitored to ensure the stored medicines or medications retain their quality and integrity. Important data are recorded in the register: date of warning, duration, highest temperature. The last five warnings are stored in the memory of the MD40DD-P301BEQ electronic controller. If the user does not delete them, they are overwritten by the FIFO method and stored in the controller’s memory.
+2 °C temperature limit
If the temperature drops below +2 °C for some critical reasons, the electronic controller immediately activates additional temperature maintenance functions along with a warning signal in order to protect the temperature-sensitive medicines and medications stored in the refrigerator.
Warning messages on the screen
The temperature warning is displayed on the controller screen until it is manually removed. This ensures that those in charge will respond in time to any critical temperature changes in the refrigerator.
Display of minimum and maximum temperature on the screen
Medicines and medications are extremely sensitive to temperature changes. For this reason, the maximum and minimum temperature values of the refrigerator can be viewed directly on the screen of the electronic controller and the causes of temperature fluctuations can be eliminated in time. The display of minimum and maximum temperatures on the screen is an additional tool for temperature control in the refrigerator.

Calibration block

TECHNICAL DATA

Pharmacy refrigerator MD14DD-P3B1QX2
EAN code 4770104014109
Gross capacity, l 130
Net capacity, l 100
Factory temperature setting, °C +5
Fluctuation, °C 0,5
Gradient, °C 2,9
Average temperature limits of products (min / max), °C From +2 to +8
Increase in temperature from +5 °C to +10 °C (empty, +25 °C TU) 40 min.
Decrease in temperature from +25 °C to +5 °C (empty, +25 °C TU) 40 min.
Ambient temperature range, °C from +10 to +35
Airborne acoustical noise emissions, dB(A) re1 pW 42
Refrigerant R600a
Daily consumption, kWh/24h 0,751
Annual energy consumption, kWh/year 274
Rated voltage, V 220 – 240
Rated frequency, Hz 50
Access port Yes
Cooling system Fan forced cooling
Defrost Automatic
Volt-free alarm contact Yes
Interior light Ceiling LED light strip
Number of shelves 3 adjustable +2 bottoms
Shelf size (W x D), mm 458 x 313, bottoms 459 x 263 and 442 x 180
Maximum load per shelf, kg 20
Shelf material Perforated metal shelves coated by white polymer pain
Side wall material Steel, white painted
Inner cabinet material HIPS polystyrene
Type of door Double panel selective glass in aluminum profile
Reversible door Yes
Self closing door Yes
Type of lock Mechanical
Adjustable foot at the front 2
Foot behind 2
External dimensions (H x W x D), mm 870 x 560 x 620
Internal dimensions (H x W x D), mm 725 x 465 x 392
Package dimensions (H x W x D), mm 1080 x 580 x 650
Weight net, kg 38
Weight gross, kg 49

 

Produktblad – Labkyl Snaige MD14DD-P6B1

 

LEASING / HYRA / AVBETALNING

Vårt samarbete med Svea gör att du snabbt och enkelt får förslag på finansiering som passar dina behov Finansiering upp till 100%. Ni slipper binda ert kapital. Läs mer om leasing och allriskförsäkring.

Investera nu i rätt utrustning, för att säkra er konkurrenskraft, kapacitet och tillgång till vital utrustning Sprid kostnaden över den tid som utrustningen används. Utrustningen som säkerhet för finansieringen.

Kontakta oss redan idag för ett förslag!

Har du lagt till produkter till ”Mina produkter” så glöm inte skicka iväg din pris- eller produktförfrågan också. Skapa gärna ett konto så sparas alla dina förfrågningarna under ”Mitt konto” sidan.